Solaris

Pyrolytic combustion, suitable for firing of dry wood logs 

Large and tall fuel loading chamber optimized for gasification process 

Dry fuel loading chamber by double wall, less condensation, higher gasification ratio, and easier surface cleaning 

Self activated by-pass system when loading door is opened

Auto swicth-off when there is no fuel

Flue gas thermostat

High efficiency due to smoke tubed water heating surface

Integrated cooling loop for protection against over-heating

Stylish electronic control board with well organized function buttons and big LCD screen

Room thermostat connection 

Primary and secondary air regulation 

Operation status and fault indicators, energy saving and safety features due to programmed PCB

  • Pyrolytic combustion, suitable for firing of dry wood logs 
    Large and tall fuel loading chamber optimized for gasification process 
    Dry fuel loading chamber by double wall, less condensation, higher gasification ratio, and easier surface cleaning 
    Self activated by-pass system when loading door is opened
    Auto swicth-off when there is no fuel
    Flue gas thermostat
    High efficiency due to smoke tubed water heating surface
    Integrated cooling loop for protection against over-heating
    Stylish electronic control board with well organized function buttons and big LCD screen
    Room thermostat connection 
    Primary and secondary air regulation 
    Operation status and fault indicators, energy saving and safety features due to programmed PCB

  • Model SOLARIS

    Types SLS 18 SLS 25 SLS 32 SLS 40 SLS 50

    Description of boiler Welded steel boiler for dry wood logs, in pyrolitic combustion principle, with negative pressure in combustion chamber driven by exhaust fan at flue

    Fuels
    Dry wood logs

    Output kW 18 25 32 40 48

    Net weight kg 405 465 480 580 680

    Water content lt 72 87 91 124 155

    Total heating surface m2 2.60 3.10 3.25 4.30 5.50

    Fuel container volume dm3 90.0 120.0 130.0 140.0 220.0

    Maximum wood log length cm 50.0 60.0

    Fuel loading clearance (H x W) mm 280x320 280x370 350x370 350x470

    Flue gas temperature C < 150

    Required draft at chimney (min-max) Pa 8 - 23


    mbar 0,08 - 0,23

    Temperature control range C 65 - 90

    Maximum operating temperature C 100

    Minimum return temperature C 65 (recommended)

    Safety system activated at C 95

    Maximum operating pressure bar 3

    Water flow/return connections ( F/R) R 1 1/2"

    Cooling loop connections (HE) R 3/4"

    Filling / draining connection (FD) R 1/2"

    External dimensions



    H mm 1325 1425 1475 1545 1545

    H1 mm 240

    H2 mm 125

    W mm 545 595 595 595 695

    L1 mm 840 855 855 855 1050

    L mm 1160 1175 1175 1175 1270

    D mm 160

    Electrical supply
    230 V / 50 Hz

    Power consumption W 50