Solaris LX

PID control

Lambda sonda

Primary and secondary air regulation

92% water efficiency

Fully electronic boiler control functions

Draught fan speed modulation controlled by encoder

Buffer probe

Large and tall fuel loading chamber optimized for gasification process

Dry fuel loading chamber by double wall, less condensation, higher gasification ratio, and easier surface cleaning

Self activated by-pass system when loading door is opened

Auto smoke pipe cleaning system

High temperature resistant cast refractory burner

Auto switch-off when there is no fuel

Flue gas thermostat

High efficiency due to smoke tubed water heating surfaces

Integrated cooling loop for protection against over-heating

  • Lambda sonda

    Primary and secondary air regulation

    Exhaust fan speed modulation

    Flue thermostat

    Auto smoke pipe cleaning

    Self activated by-pass system

    PID control

    Lambda sonda

    Primary and secondary air regulation

    92% water efficiency

    Fully electronic boiler control functions

    Draught fan speed modulation controlled by encoder

    Buffer probe

    Large and tall fuel loading chamber optimized for gasification process

    Dry fuel loading chamber by double wall, less condensation, higher gasification ratio,  and easier surface cleaning

    Self activated by-pass system when loading door is opened

    Auto smoke pipe cleaning system

    High temperature resistant cast refractory burner

    Auto switch-off when there is no fuel

    Flue gas thermostat

    High efficiency due to smoke tubed water heating surfaces

    Integrated cooling loop for protection against over-heating

    Outputs configuration: Several outputs can be controlled such as two circulating pumps (one for heating, one for domestic hot water supply), one heating pump with either 3-way mixing valve, or diverting valve.

    Approvals;

    EN 303-5 Class 5

    Eco Design Directive (2015/1189)

    Complies;

    1.BImSchV Level 2

  • Model SLS 25 LX
    Fuels   Dry wood logs
    Output  kW 25
    Water content lt 87
    Total heating surface m2 3.10
    Fuel container volume dm3 120
    Maximum wood log length cm 50
    Fuel loading clearance (H x W) mm 280x370
    Flue gas temperature C < 125 
    Required draft at chimney (min-max) Pa 8 - 12
      mbar 0,08 - 0,12
    Temperature control range C 60 - 90
    Maximum operating temperature C 100
    Minimum return temperature C 55 (recommended)
    Safety system activated at C 95
    Maximum operating pressure bar 3
    Water flow/return connections ( F/R) R 1 1/2"
    Cooling loop connections (HE) R 3/4"
    Filling / draining connection (FD) R 1/2"
    Electrical supply   230 V / 50 Hz
    Power consumption W 60