Optimus

Medium efficiency solution for gasification boilers 

Pyrolytic combustion, suitable for firing dry wood logs 

Large and prismatic fuel loading particulary sized for better gasification process 

Manually activated by-pass mechanism 

High efficiency due to increased effective water cooled heating surface after combustion 

Integrated cooling loop for protection against over-heating 

Stylish electronic control board with well organized function buttons and LCD 

Auto swicth-off when there is no fuel 

Room thermostat connection 

Effective primary and secondary air regulation with good combustion air distribution result in high gasification 

Exhaust fan assisted combustion with modulation on motor speed 

High quality steel in constructioni durable materials on burner and ash pan 

Reduced polluting emissions, small quantity of ash

  • Medium efficiency solution for gasification boilers 
    Pyrolytic combustion, suitable for firing dry wood logs 
    Large and prismatic fuel loading particulary sized for better gasification process 
    Manually activated by-pass mechanism 
    High efficiency due to increased effective water cooled heating surface after combustion 
    Integrated cooling loop for protection against over-heating 
    Stylish electronic control board with well organized function buttons and LCD 
    Auto swicth-off when there is no fuel 
    Room thermostat connection 
    Effective primary and secondary air regulation with good combustion air distribution result in high gasification 
    Exhaust fan assisted combustion with modulation on motor speed 
    High quality steel in constructioni durable materials on burner and ash pan 
    Reduced polluting emissions, small quantity of ash

  • Model OPTIMUS
    Types OTS 15 OTS 22 OTS 30 OTS 38 OTS 48 OTS 60 OTS 80
    Description of boiler Welded steel boiler for dry wood logs, in pyrolitic combustion principle, with negative pressure in combustion chamber driven by exhaust fan at flue
    Fuels

    Dry wood logs
    Output kW 15 22 30 38 48 60 80
    Efficiency % 81 - 83
    Flue gas temperature C 135 - 175
    Flue gas mass flow g/s 15.0 21.0 28.5 36.0 45.5 57.0 75.5
    Water content lt 60 74 85 97 114 138 161
    Maximum wood log length cm 50.0 50.0 50.0 60.0 70.0 70.0 80.0
    Fuel loading chamber volume dm3 73 83.0 108.0 120.0 165.0 202.0 277.0
    Fuel loading clearance (upper door) cm2 905 1195 1195 1315 1315 1660 1660
    Temperature control range C 65 - 90
    Maximum operating temperature C 100
    Minimum return temperature C 65 (recommended)
    Safety system activated at C 95
    Maximum operating pressure bar 3
    Water flow/return connections (F/R) R 1 1/2" 2"
    Cooling loop connections (HE) R 3/4"
    Filling / draining connection (FD) R 1/2"
    External dimensions







    H mm 1060 1090 1210 1210 1290 1290 1390
    H1 mm 560 780 900 900 980 980 1080
    H2 mm 190 160 160 160 160 160 160
    H3 mm 55 55 55 55 55 55 55
    W mm 475 535 535 535 535 615 615
    L1 mm 648 648 648 748 848 848 958
    L mm 1050 1050 1050 1170 1270 1270 1420
    D mm 168 180
    Electrical supply
    230 V / 50 Hz
    Power consumption W 70 110