Cortina

Automatic Ignition 

From 12 up to 45 Kw 

Compact Dimensions 

High Grade Stainless Steel Burning Pot 

Flexible Build with a variety of configurations 

PID control Adjustable boiler Outputs 

Fire Protection System, Safety Aganist Back Burning 

Exhaust Fan Speed Modulation By outlet water temperature and flue gas temperature 

Vertical flue circulation princible 

Pellet level monitoring window 

High heating surface with vertical flue circulation princible 

High water efficiency and very low polluting emissions (EN 303/5 class 5 approval) 

Auto swicth-off when there is no fuel

  • The Cortina pellet boiler is sel cleaning, compact pellet boiler with very high yield of %90 on avarage Eligible for subsidy at most of EU country. 

    Automatic Ignition 
    From 12 up to 45 Kw 
    Compact Dimensions 
    High Grade Stainless Steel Burning Pot 
    Flexible Build with a variety of configurations 
    PID control Adjustable boiler Outputs 
    Fire Protection System, Safety Aganist Back Burning 
    Exhaust Fan Speed Modulation By outlet water temperature and flue gas temperature 
    Vertical flue circulation princible 
    Pellet level monitoring window 
    High heating surface with vertical flue circulation princible 
    High water efficiency and very low polluting emissions (EN 303/5 class 5 approval) 
    Auto swicth-off when there is no fuel

  • Model CORTINA
    Types CT 12 CT 18 CT 24 CT 32 CT 40
    Fuel specifications Wood pellets size 6 mm to EN 14961
    Maximum power output kW 15 20 26 34 45
    Minimum power output kW 4.5 5.7 7.8 10.2 13.5
    Efficiency at max output % 91.2 88.8 89 89.1 89.3
    Efficiency at min output % 89.3 88.9 89.2 88.4 89.5
    Flue gas temperature at max power C 116 119 125 124 113
    Flue gas temperature at min power C 84 73 80 90 79
    Water content lt 44 40 45 70 76
    Fuel container capacity kg 50 58 90 100

    lt 88 106 162 190
    Minimum return temperature C With non-condensing working conditions
    Flue gas mass flow Qmax g/s 13 16 21 25 30
    Flue gas mass flow Qmin g/s 6 7 9 10 12
    Required draft at chimney Pa 8 10 12-15
    Temperature control range C 45- 80
    Max operating temperature C 80
    Max operating pressure bar 3
    Water flow/return (F / R) DD DG 1 " (male)
    Filling/draining connection (FD) R ½ " (male)
    External dimensions






    H mm 1365 1490 1620 1670
    H1 mm 1195 1235 1360 1490 1540
    H2 mm 1050 1085 1210 1340 1390
    H3 mm 300 325 360
    W mm 730 850 900
    L mm 525 575 625
    D mm 127
    Electrical supply
    230V / 50Hz
    Power consumption (fan+feeder motor) W 75 71
    Power consumption (ignitor) W 165
    Airborne noise (run mode ) dB 45-55